Piercing well digging
I do the cold water friction (cold water shower) for treatment and the health enhancement of the chronic rheumatism
every morning. The desire well decided to be dug up whether to do by the well
water because it was thought that it was too cold for the wife in it was and
winter when water painted the life in summer.
It dug up the piercing well for myself by the method to find
by the following Internet. Because it was possible to dig well, it introduces
it. We wish to express our gratitude to Mr.Sogabe and the well digging
mailing list.
How to dig up piercing well
The piercing well (well and ..stamping out.. ..driving.. well)(It seems to
be called a driving well) doesn't dig up the large range, and it is possible to
dig up the amount of the dug soil with an easy tool few, and compared it. It
would be greatly appreciated though it cannot be said that the method done by me
is good when the result of the trial and error serves as a reference.
First of all, only being possible to dig with the shovel etc. digs up the
range of 30-50cm in the diameter. It is likely to be able to dig up about 1m in
depth.
Next, it digs by pumping water in to the hole with the well digging
container of handmade. How to dig exhausts the well digging container, and it
moves, the soil up which it digs in the valve of the well digging container is
taken up and down, it pulls out up, and the soil is exhausted with ton ton. It
digs by this repetition.
It was possible to dig for me only with the well
digging container because it was a clay chiefly layer, and I think that it digs
piercing the soil of the bottom with crushing the iron pipe ahead and softening
the soil easily for a usual soil.
I made the well digging container with
the vinyl pipe of VU50. Please refer to the explanation of the photograph for
how to make.
When it is possible to dig to some degree, the pipe of VP75
is put as a well frame (It is said the well side). Because I was able to
obtain only VU75, VU75 was used. A lot of holes to which the water of about
Dia. 4mm is taken are made for the vicinity of the point of the pipe. The
method of inserting the pipe seems should beat with the hammer, and hang
the weight of the block. Moreover, there is information of smoothly entering
when putting it while moving the pipe up and down, too.
I fail in the insertion of the pipe, and
enter the state that the put thing cannot be pulled out. The pipe was able to be
inserted only up to 3m. I think everything to be difficult in argillaceous. The
pipe of VU50 was put reluctantly the inside as the well frame. After it had dug
up everything, this well frame pipe was put. The hole of the dug well narrowed a
little when taking a rest from the well digging by about two weeks, and work to
expand the hole again was needed. When the well frame pipe is put later, might
the good policy digging at a dash.
How to make the well digging container and How to use.
Above-mentioned Mr. Sogabe is designed as for this well digging container, and there is not a problem to produce personally and to use it while seeming to apply for the utility model either. When it is sold to produce this, Mr. Sogabe's permission is necessary.
![]() |
The main tool is only a well digging container. The pipe of VU50 is cut in
about 50cm and the pipe patch person of VP50 is installed below only with the
tap machine screw of 4mm as shown in the photograph. (To enable changing.
) The valve to take the soil into pipe connection's center is installed. I made the edge and the valve from the galvanized iron. The installation of the valve was bound with a stainless wire of Dia. 1.4mm. The blade to dig was put up most below. This was useful to dig up a hard clay layer. It went well when digging while rotating the well digging container at this time. It comes off well though it digs up the well digging container while rotating to the right when the hole of about Dia. 10mm is made for the tie part of VP20, it inserts, it turns to the hole the driver ahead, and it removes because it becomes difficult to remove by the screw's in the tie part of VP20 shutting. |
|
| The hole to exhaust the soil to VU50 is made. About 20 holes of about Dia. 4mm are made from this exhausted hole for the whole below for the water pulling out. | ||
![]() |
The upper part of VU50 installs the patch person of the strange
appearance, and installs the surgical knife screw of VP20 finally. The pipe of
VP20 of 4m is added with the screw. It not only pastes about the chloridization
vinyl but also taking out of the bottom of a well screws in the tap machine
screw in the joint part for attention because it is difficult if the joint part
comes off by any chance. The well frame of VU50 was put in the well where it was able to dig up a left photograph. A well digging container and inside well frame is the same thickness. It sees it fairly unlike in the photograph. It doesn't puncture it on the side under the well frame. The intake of the water of the well frame is only the lower side. The depth of the well is 8m80cm. |
|
It ..well.. is digging.
![]() |
The taking turning of the well digging container became difficult when the
depth of the well became five meters or more, it went up on the stepladder, and
it dug though it dug from the ground at first because the depth of the well was
shallow. The method of digging putting up every four meters and removing the pipe of the well digging container by well digging ML afterwards was taught. It dug up the removed pipe of four meters by the method of leaning against the building of total Nicai in by the side soon and putting. |
| Geological features were decomposed granite soils up to 1m, and
soft clay layers from 1 to 8m. From 8m to 8m70cm was a hard clay layer. The last
10cm dug quite in the gravel bed and it did not advance it. It dug up to 8m and it advanced it on the second day of 6m in the day. It took one week or more by 80cm afterwards. |
|
The well water finally came out.
![]() |
It started giving it up because it had already dug saying as it was
possible to dig up the well and it did not advance it. However, after the well
frame pipe had been put thinking that water came out if it was a gravel bed, the
well water was pulled out with the pump. The space between the inhalation hoses of the well frame and the pump has packed the tube of the bicycle so that air should not enter, and when this drains it for a long time, it is not effective either. It is because air enters little by little. Water came to come out continuously when pulling it out many times with the pump though water did not come out quite well. An underground water title Yattar usual is from the ground to about 1.5m. |
|
| The one that about 500 holes of Dia. 3.5mm were made within
the range of 20cm the pipe of VP20 that shut ahead ahead was installed
in the intake of the well water so that a small stone should not enter.
It is stopped up at once in the thing that has placed to the bought pump
with sand. 2003.08.22 |
||
The well is sealed up and the pump is installed.
![]() |
The well was completely sealed up so that the pump may first bite air and
make it not crowd. The hole that VU50 passes to the cap of VU75 is made and VU75
and VU50 are fixed as shown in the photograph. The space between VU75 and VU50
packed the clay dug out and stuffed with caulking most up. Next, it converts it
from VU50 to VU40 with VP20 and the strange appearance socket. The strange appearance socket to VP20 was finished up little by little with the file so that the pipe of VP20 for sucking up might penetrate. The point of the pipe for sucking up is put in the place of the octonary.8 m below most. It bonded completely with the adhesive of the vinyl chloride without thinking about the thing that had already been removed. The sand removing container was installed in the sucking up pipe at once. Because strainer of the sucking up pipe sticks to the bottom of a well, the sand removing container is necessaries. The pump is PAL-2531BR of SANSO ELECTRIC. It is a fixed pressure automatic pump and motor output 250W. |
|
| The pipe on the side of pushing out was laid with VP20. The hole
was made from the earth for the concrete of the base and it was assumed the
below the floor level piping. When it keeps exhausting the well water by continuously driving the pump, water becomes transparent in the vicinity as for 3-4 though the turbid water comes out at first. At first, the sand removing container is cleaned every day. You may hardly do sooner or later. |
||
The well and the pump are put in a concrete well frame.
![]() |
![]() |
| The well and the pump were put in a concrete well frame (Idutsu) of 75cm
in the inside diameter for a reduction, a freeze proofing, a direct sunshine
avoiding, a rain avoiding, and mechanical protection of the noise. Idutsu's lid
painted the coal tar on the waterproof and preservative making it from the board
of the tree of about 2cm thickness. The knob was put up. I think lasting long
though externals are bad. The wiring for 100V was assumed to be underground piping with the cable of VVFDia. 2.0mmX2 for electrical work. |
The faucet for the well water is installed.
![]() |
VP20 was laid in the below the floor level, and a special faucet was
installed in the outside wall. The vicinity of the faucet was laid with the
copper pipe of 7/8 inches because there was no strength in VP20. There is
strength from a right faucet. The ground sink was incidentally made from the brick. Might be made. There is an amount of spring water during about eight liter/minute and this can be used even because of putting out 24 hours. If it is a left photograph, it is possible to use it even by when. |
|
| The amount from which the well water after the faucet is opened
comes out is as follows. For 0-15 seconds----5.5 liters For 15-30 seconds---3.0 liters For 30-45 seconds---2.1 liters For 45-60 seconds---2.0 liters Total of 60 seconds---12.6 liters Water temperature---17.0 degree centigrade PH = 7.9 (Tap water was PH=6.8) It was cold and it was pleasant though the cold water shower had been done by the well water. There seems to not be so much usage because a little yellow color has adhered to water. It seems to be able to use the schedule at first for the cold water friction cooling the water scattering in the garden and the watermelon. 2003.09.08 |
||
Power consumption and power factor measurement of well pump
The power consumption of the motor used for the pump was measured though
did not know how much electric power used while driven a variety of in spite of
writing as 500W. The measuring instrument is M-3860M of METEX that can measure a
true electric power.
It is time when the least power consumption
completely opens the faucet, and becomes the lowest the volume of water. At this
time, power factor was 1.0 by about 295W.
It is immediately before
motor the pressure of the accumulator reducing the volume of water from the
faucet, becoming the maximum, and stopping becoming the maximum electric power
consumption. At this time, it was power factor 1.0 by about 490W.
The
power factor of the motor is 0. Because it is a capacitor motor, is moment of
force good though it was thought 8th place?It was between from 0.99 to 1.0.
Cross section of well
![]() |
To make easily to understand in the sight, the cross section of the well
was made. Having put strainer the under thinks that it drives and digs up the iron pipe the same as the driving well. From bottom of a well to strainer because thing buried in sand is understood sooner or later sand goes up from the under on about 30cm-50cm as for strainer The clay dug out was packed between VU75 and VU50. I think that clay is better because it causes water on and on the way to enter though there is a person who packs sand and a small stone into here, too. There seems to be a hydrogen sulfide gas now though it thought this space to be must be lost because this air melts to water in the space on between VU50 and VP20 sooner or later now though there is air. I think that it was able to dig well only because it fails in the insertion of VU75. |
|
| Formation of stratum around
here The place in the gravel bed of 8.7 meters in the underground seemed to have been surface of the earth at the last last glacial epoch of the diluvial epoch about 20,000 years ago. The glacier seemed to be relieved afterwards, to rise the surface of the sea, to pile up in [Tyusekisei] the clay layer, and to have been formed this stratum. About the first term of Jomon seemed to decrease gradually afterwards because of the peak the surface of the sea and to have become present Okayama plains in the surface of the sea. |
||








